Select Page

VME 64x 3U 165 Series

Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. Over the evolution of its near 40 years of existence, VME-bus has become a worldwide standard and is still used in a wide variety of applications across many different markets. Hartmann’s innovation in cost effective design benefits customers in diverse industries including military, transportation, medical imaging, telecom, industrial controls, and aerospace.

The 3U 165 Series for VME64x boasts a variety of configurations to fit a complex array of needs. Available in 3, 9, 10 and 21 slot configurations, there is an option for every need. Talk to a Hartmann representative today to see which configuration will work for you!

Additional Information

Form Factor

3U J1

Slots

10, 21, 3, 9

Slot Pitch

4HP (20.32 mm)

Power Consumption, Both Ends Terminated

Active: < 0.1A, Passive: < 1.6A

Power Supply Connection

Terminal bar / screw terminal M6

Daisy Chaining/Bus Grant

Electronic automatic (OR gate), Manual (jumper or wire wrap, on request)

Permissible Current Load

200A terminal bar, 25A combined double spade/ screw connection, 10A Faston connector

Permissible Current Load Per Slot

+3.3V 12.5A, +5V 9.0A, +12V 1.5A, -12V 1.5A, +5V Standby 1.5A, +48V (38-75V) 3.0A

Termination ON/IN Board

Active, Passive

PCB Design

Optimized for best HF behavior

Base Specification

ANSI/VITA 1.1-1997

Base Material

Type FR-4

Ohmic Resistance

< 1.5 Ohm

Surge Impedance Z of Signal Lines

60 Ohm

Chassis GND

Continuous chassis GND surface where backplane is mounted to rack., HF coupling of rack and system ground implemented by capacitors (10nF, 200V each slot). Chassis ground combination M6 screw / Faston 6.3 x .8 mm

Card Thickness

4.3 mm (.17")

Connectors

160 pin, 2 mm press-fit, quality grade 2

Operating Temperature

Active: 0°C … +70°C, Passive: -40°C … +85°C

Relative Humidity

90%, non-condensing

Part No.HeightDaisy Chaining/Bus GrantTermination ON/IN BoardDatasheet
B1654_ _ A7D3UElectronic automatic (OR gate)Active

NA

B1654_ _ A7B3UManual (jumper or wire wrap, on request)Active

NA

_ _ = Number of slots

Contact Us

Discover how Hartmann can increase power, speed and rugged durability to your project performance.

Hartmann Electronic

Germany Headquarters
Motorstr. 43
D-70499 Stuttgart, Germany
P:+49 711 13 98 90
North American Office
202 N. Limestone St. Suite 320
Springfield, Ohio 45503
P:+1 937-324-4422
  • Hidden
  • This field is for validation purposes and should be left unchanged.